P0429 Acura Catalyst Heater Control Circuit Bank 1
– Catalyst Temperature Sensor harness is open or shorted
– Catalyst Temperature Sensor circuit poor electrical connection
The Engine Control Module (ECM) monitors the switching frequency ratio of heated oxygen sensors 1 (front O2 sensor) and heated oxygen sensors 2 (rear O2 sensor).
A three way catalyst converter (Manifold) with high oxygen storage capacity will indicate a low switching frequency of heated oxygen sensor 2. As oxygen storage capacity decreases, the heated oxygen sensor 2 switching frequency will increase.
When the frequency ratio of heated oxygen sensors 1 and 2 approaches a specified limit value, the three way catalyst malfunction is diagnosed.
Acura Vehicle:
Acura ILX, Acura MDX, Acura RDX, Acura RLX, Acura TL, Acura TSX, Acura ZDX, Acura CSX, Acura EL, Acura Integra, Acura RSX, Acura Legend, Acura Vigor, Acura CL, Acura SLX, Acura NSX, Acura RL, Acura ZDX