P0405 Opel Exhaust Gas Recirculation Position Sensor Circuit Low Voltage
– EGR volume control solenoid valve harness is open or shorted
– EGR volume control solenoid valve circuit poor electrical connection
– EGR temperature sensor and circuit
– Possible engine hesitation
An Exhaust Gas Recirculation (EGR) system is used in order to lower Oxides of Nitrogen (NOx) emission levels. The EGR system accomplishes this by feeding small amounts of exhaust gas back into the combustion chamber. High combustion temperatures cause NOx. Combustion temperatures are reduced when the air/fuel mixture is diluted with the exhaust gases.
The EGR valve is designed to accurately supply exhaust gases to the engine without the use of intake manifold vacuum. The EGR valve controls the exhaust flow into the intake manifold from the exhaust manifold through an orifice with a Powertrain Control Module (PCM) controlled pintle. The PCM controls the pintle position using inputs from the Throttle Position (TP) sensor, the Manifold Absolute Pressure (MAP) sensor and, the Engine Coolant Temperature sensor. The PCM commands the EGR valve in order to supply the correct amount of exhaust gas recirculation for the current engine operating conditions.