إدراج السيارة هو نقطة بداية للبحث. تحقق من المحرك وفترة الإنتاج والبرمجيات في معلومات الشركة المصنعة.

ملخص الشركة

النص الأصلي بالإنجليزية

SMOG Test will not complete successfully. NOTE: Customers may come to dealership as instructed by ISP (Independent Service Provider) based on instructions from a TSB (Technical Service Bulletin). Access to the TSBs can be found via https://www.obdclearinghouse.com/ or by viewing the TSBs in the attachments area of this LI. Cause In the event the Engine Control Module (CDI) detects a fault with the Water Pump Short Circuit to Battery diagnostic, Fault Code P260312 and/or P260315 may set and prevent the readiness monitor from running. Even following a successful repair and/or clearing the Fault Code(s), the readiness monitor remains deactivated and self-healing is not possible. This deactivation may prevent the vehicle from passing state emissions inspection and SMOG Test and is only resolvable by installing new engine control unit software. Remedy 1. Perform XENTRY Quick Test. 2. Check for the presence of Fault Code P260312 and/or P260315 in the CDI control module. 3. If relevant Fault Codes are present, resolve fault using standard dealer procedures. 4. If no relevant Fault Codes are present, or the fault has been repaired and Fault Codes erased, proceed to check and install new Engine Control Unit SW

نشرات الشركات لدى NHTSA ↗

نجمع فقط التسجيلات ذات الشركة والرقم والتاريخ والملخص الكامل المتطابقة ونحتفظ بالأرقام والوثائق القديمة. نعرض الاستبدالات الصريحة المثبتة فقط. تُفصل علاقات ما قبل 1994 عن النتائج الافتراضية. عدم تحديد السنة لا يعني كل السنوات.