MERCEDES-BENZ
LI47.70-N-079913
2025-11-12 · NHTSA 11026052
إدراج السيارة هو نقطة بداية للبحث. تحقق من المحرك وفترة الإنتاج والبرمجيات في معلومات الشركة المصنعة.
ملخص الشركة
النص الأصلي بالإنجليزية
Vehicle not starting after DC charging Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit) • P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit. • P154A00 - There is a warning due to a detected crash event at standstill. • P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit) • P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal. • P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed • P2BCC00 - The contact ''Negative terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed. Remedy • Check for a new software availability for DCCU (N24/6 - Direct Current Charge connection Unit). If a new software is available, update the software first. • Reset contactor fault through special procedure without password. ( N24/6 >> Special Procedure >> Resetting of contactor fault.)
نشرات الشركات لدى NHTSA ↗نجمع فقط التسجيلات ذات الشركة والرقم والتاريخ والملخص الكامل المتطابقة ونحتفظ بالأرقام والوثائق القديمة. نعرض الاستبدالات الصريحة المثبتة فقط. تُفصل علاقات ما قبل 1994 عن النتائج الافتراضية. عدم تحديد السنة لا يعني كل السنوات.