MERCEDES-BENZ, MERCEDES-MAYBACH
LI82.85-P-080507
2026-05-26 · NHTSA 11033185
إدراج السيارة هو نقطة بداية للبحث. تحقق من المحرك وفترة الإنتاج والبرمجيات في معلومات الشركة المصنعة.
ملخص الشركة
النص الأصلي بالإنجليزية
Complaint After successful commissioning of the HERMES control unit (N112/9) with XENTRY Diagnosis DVD 03/2026, the message "SOS - service not activated" appears on the instrument cluster. In addition, the following two conditions are also met: • HERMES (N112/9) control unit: event code B15CE00 is ACTIVE and STORED (A+S) • Vehicle Documentation System: For the HERMES control unit, the EID1, EID2, ICCID, IMEI, IMSI, TELNR fields in the "Identification/Serial number" column have the value "-" Cause Still under analysis Remedy Recommission the HERMES control unit (N112/9) with XENTRY Diagnosis 03/2026 and add-on 33399 installed or carry out the procedure with a newer version of XENTRY Diagnosis: XENTRY→ "N112/9 - Control unit for telematics services (HERMES)" -> "Adaptations" -> "Control unit commissioning" -> "Commissioning of previously installed control unit"