MERCEDES-BENZ
LI47.70-P-076030
2026-02-24 · NHTSA 11029061
A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.
Manufacturer summary
Original wording in English
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"
NHTSA manufacturer communications ↗Repeated filings are grouped only when make, bulletin number, publication date and complete summary agree. Original record numbers are retained. Older publications remain available, and an explicit later version is shown when established. Pre-1994 vehicle associations are separated from default results; an unspecified year does not mean all model years apply.