MERCEDES-BENZ, MERCEDES-MAYBACH
LI80.20-P-078308
2026-03-23 · NHTSA 11030300
A listed vehicle is a research lead. Confirm the engine, production range and software in the manufacturer's information.
Manufacturer summary
Original wording in English
Complaint Depending on the identified problem (items 1-4), please implement the corresponding Remedy below (items 1-4): 1. KeylessGo sensor surfaces do not respond. Door handles can extend/retract if the key is used for locking/unlocking. No particular fault code. 2. Surface-flush door handle fails to retract and/or extend. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_bridge_connection_fatal_error = True (for example, see attachment) OR Motor_bridge_wrong_direction_fatal_error = True (for example, see attachment) 3. Surface-flush door handle fails to retract and/or extend. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_init_error_for_sensors = True (for example, see attachment) 4. Surface-flush door handle fails to retract and/or extend. The fault code B185911 is stored in the DCU (N69/X). Cause 1. Software bug. 2. Software robustness. 3. Software robustness. 4. The motor resistance is outside the tolerance range. Remedy Depending on the identified Complaint above (items 1-4), please implement the corresponding remedial actions (items 1-4): 1. Perform a reset of the corresponding 'KEYLESS GO' door handle control unit (A17/x) via XENTRY (for example see attachment) add-on is available (add-on 32204 for XENTRY version 06/25) Please use one of the following damage codes: 8213H73; 8219773; 8213K73; 8219873 2. Please process the guided fault check via XENTRY (Add-on 32485 for XENTRY version 06/25; Add-on 32486 for XENTRY version 09/25). In the event of a proposed SCN coding, it must be carried out and the faults must then be cleared. Please use one of the following SSLs: 8213H73; 8219773; 8213K73; 8219873 3. Please process the guided fault check via XENTRY (Add-on 32485 for XENTRY version 06/25; Add-on 32486 for XENTRY version 09/25). In the event of a proposed renewal of the bearing bracket, the corresponding bearing bracket must be replaced. Please use one of the following SSLs: 80A0D73; 80N0D73; 80N0E73; 80A0E73 4. The motor resistance is too low. Bearing bracket must be replaced. Please use one of the following SSLs: 80A0D73; 80N0D73; 80N0E73; 80A0E73 Please note that other published GI documents may also be valid for assessing the problem. For example: "LI72.10-P-074316 Flush-Mounted Door Handle Jams When It Is Pulled Out". Please also refer to SI72.00-P-0014A in WIS. If after the remedy points above are performed, the problem is still present, please submit a TIPS case to the PTS-Body/Chassis/Entertainment inbox. → In this case, store the damaged parts for further analyses.
NHTSA manufacturer communications ↗Repeated filings are grouped only when make, bulletin number, publication date and complete summary agree. Original record numbers are retained. Older publications remain available, and an explicit later version is shown when established. Pre-1994 vehicle associations are separated from default results; an unspecified year does not mean all model years apply.