MERCEDES-BENZ
LI54.10-P-077250
2024-12-11 · NHTSA 11011846
La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.
Resumen del fabricante
Texto original en inglés
Complaint Customer states CEL is on. Cause Quick test shows FC P0A7F00 The state of health limit of the hybrid/high-voltage battery module has been reached. No drivability concerns occurred and vehicle drives as normal. Remedy Do not replace any parts!! 254: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 51 75 MY24 206: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 52 75 After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.
Comunicaciones de NHTSA ↗Solo agrupamos registros con fabricante, número, fecha y resumen completo idénticos. Conservamos los identificadores y documentos antiguos; marcamos sustituciones explícitas confirmadas. Las relaciones anteriores a 1994 se separan de los resultados predeterminados. Año no indicado no significa todos los años.