MERCEDES-BENZ
LI47.70-P-076030
2026-02-24 · NHTSA 11029061
La relación con un vehículo es una pista. Confirma motor, producción y software en la documentación del fabricante.
Resumen del fabricante
Texto original en inglés
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"
Comunicaciones de NHTSA ↗Solo agrupamos registros con fabricante, número, fecha y resumen completo idénticos. Conservamos los identificadores y documentos antiguos; marcamos sustituciones explícitas confirmadas. Las relaciones anteriores a 1994 se separan de los resultados predeterminados. Año no indicado no significa todos los años.