देखें

MERCEDES-BENZ

LI47.70-P-076030

2026-02-05 · NHTSA 11028610

सूची में वाहन का होना जाँच की शुरुआत है। निर्माता की जानकारी में इंजन, उत्पादन अवधि और सॉफ़्टवेयर जाँचें।

निर्माता सारांश

मूल अंग्रेज़ी विवरण

Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The instrument cluster message and the FC memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For model series 206 and 223 with code 802: Perform a software update and SCN coding for the control unit "N83/11 - AC charger for high-voltage battery (SGLG)" in order to remedy the problem. For model series 243: The correction is already available. Perform a software update and SCN coding for the control units "N116/5 - Direct current charging connection unit (DCCU)" and "N83/11 - AC charger for high-voltage battery (SG-LG)" in order to remedy the problem.

NHTSA निर्माता जानकारी ↗