देखें

MERCEDES-BENZ, MERCEDES-MAYBACH

LI80.20-P-078308

2026-02-27 · NHTSA 11029090

सूची में वाहन का होना जाँच की शुरुआत है। निर्माता की जानकारी में इंजन, उत्पादन अवधि और सॉफ़्टवेयर जाँचें।

निर्माता सारांश

मूल अंग्रेज़ी विवरण

Complaint Please perform the corresponding remedy measures (points 1-4) depending on the determined problem (points 1-4): 1. KeylessGo sensor surfaces do not respond. Door handles can extend/retract if unlocked/locked using the key. No particular fault code. 2. Flush-fitting door handle does not extend and/or retract. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_bridge_connection_fatal_error = True OR Motor_bridge_wrong_direction_fatal_error = True (see attachment for example) 3. Flush-fitting door handle does not extend and/or retract. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_init_error_for_sensors = True (for example, see attachment) 4. Flush-fitting door handle does not extend and/or retract. The fault code B185911 is stored in the DCU (N69/X). Cause 1. Software bug. 2. Software robustness. 3. Software robustness. 4. The resistance of the motor is outside of tolerance. Remedy Please perform the corresponding remedy measures (points 1-4) depending on the determined problem (points 1-4): 1. Perform a reset of the corresponding 'KEYLESS GO' door handle control unit (A17/x) via XENTRY (for example see attachment) add-on is available (add-on 32204 for XENTRY version 06/25) Please use one of the following damage codes: 8213H73; 8219773; 8213K73; 8219873 2. A control unit event log for the component part concerned (A17/x) must be created and the following values checked in the "Component Errors" section: Motor_bridge_connection_fatal_error = True (for example, see attachment) OR Motor_bridge_wrong_direction_fatal_error = True (for example, see attachment) If one of the values is "True": Perform an SCN coding on the corresponding 'KEYLESS GO' door handle control unit (A17/x) via XENTRY add-on is available (add-on 32280 for XENTRY version 06/25) The faults must be deleted after SCN coding. Please use one of the following damage codes: 8213H73; 8219773; 8213K73; 8219873 3. A control unit event log for the component part concerned (A17/x) must be created and the following value checked in the "Component Errors" section: Motor_init_error_for_sensors = True (for example, see attachment) If the value is "True": Bearing bracket must be replaced. Please use one of the following damage codes: 80A0D73; 80N0D73; 80N0E73; 80A0E73 4. The motor resistance is too low. Bearing bracket must be replaced. Please use one of the following damage codes: 80A0D73; 80N0D73; 80N0E73; 80A0E73 Please note that other published GI documents may also be valid for assessing the problem. For example: "LI72.10-P-074316 Flush-Mounted Door Handle Jams When It Is Pulled Out". If after the remedy points above are performed, the problem is still present, please submit a TIPS case to the PTS-Body/ Chassis/Entertainment inbox. → In this case, store the damaged parts for further analyses.

NHTSA निर्माता जानकारी ↗

केवल समान निर्माता, नंबर, तारीख और पूरे सारांश की प्रविष्टियाँ समूहित हैं। मूल नंबर और पुराने दस्तावेज सुरक्षित हैं; पुष्ट स्पष्ट प्रतिस्थापन दिखते हैं। 1994 से पहले के संबंध सामान्य परिणामों से अलग हैं। वर्ष न बताया जाना सभी वर्षों का समर्थन नहीं है।