POSSIBLE CAUSES
- ECM GROUND CIRCUIT(S) OPEN
- FUSED B+ CIRCUIT OPEN
- FUSED IGNITION SWITCH OUTPUT CIRCUIT OPEN
DIAGNOSTIC PROCEDURE
NOTE: Refer to VERIFICATION TESTS for appropriate verification test procedures.
- Turn the ignition off. Disconnect the ECM harness connectors. Using a 12-volt test light connected to 12-volts, check each of the ECM ground circuits in ECM harness connector. Did the test light illuminate for each cavity?
Yes –> Go To 2
No –> Repair the ECM Ground circuit(s) for an open. - Turn the ignition off. Disconnect the ECM harness connectors. Turn the ignition on. Using a 12-volt test light connected to ground, check the Fused Ignition Switch Output circuit in ECM harness connector. Is the test light on?
Yes –> Go To 3
No –> Repair the Fused Ignition Switch Output circuit for an open. - Turn the ignition off. Disconnect the ECM harness connectors. Using a 12-volt test light connected to ground, check each Fused B+ circuit in the ECM harness connector. Does the test light illuminate brightly for each circuit?
Yes –> Test Complete.
No –> Repair the Fused B+ Output circuit for an open.