MERCEDES-BENZ
LI54.10-P-077250
2024-12-11 · NHTSA 11011846
掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。
メーカー概要
英語の原文
Complaint Customer states CEL is on. Cause Quick test shows FC P0A7F00 The state of health limit of the hybrid/high-voltage battery module has been reached. No drivability concerns occurred and vehicle drives as normal. Remedy Do not replace any parts!! 254: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 51 75 MY24 206: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 52 75 After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.
NHTSA メーカー資料 ↗メーカー、番号、発行日、全文概要が一致した登録だけをまとめ、元番号を残します。古い資料も保持し、明示的に確認できた後続版を表示します。1994年以前の車両との関連は通常結果から分離します。年式未記載は全年式への適用を意味しません。