掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。
メーカー概要
英語の原文
Complaint One of the flush door handles (Also referred to as Seamless Door Handles) does not extend/retract (and/or) the KeylessGo sensor surfaces do not respond. Cause Multiple possible causes can be inferred from the table, see remedy (additionally as reference table in attachment). Remedy 1) KeylessGo sensor surfaces do not respond. Door handles can extend/retract if the key is used for locking/unlocking. No particular fault code. Perform an A17/x (handle controller) reset via XENTRY (for example see attachment - under actuations tab for A17/x controller) -> add-on is available (add-on 32204 for XENTRY version 06/25) Please use one of the following damage codes: 8213H; 82197; 8213K; 82198 2) Surface-flush door handle fails to retract and/or extend One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 A control unit event log for the component part concerned (A17/x) must be created and the following values checked in the "Component Errors" section: Motor_bridge_connection_fatal_error = True (for example, see attachment) OR Motor_bridge_wrong_direction_fatal_error = True (for example, see attachment) If one of the values is "True": Perform an SCN coding on the door handle A17/x via XENTRY -> add-on is available (add-on 32280 for XENTRY version 06/25) The faults must be deleted after SCN coding. Please use one of the following damage codes: 80A0F; 80N0F; 80N0G; 80A0G 3) Surface-flush door handle fails to retract and/or extend One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 A control unit event log for the component part concerned (A17/x) must be created and the following value checked in the "Component Errors" section: Motor_init_error_for_sensors = True (for example, see attachment) If the value is "True" Bearing bracket must be replaced. Please use one of the following damage codes: 80A0F; 80N0F; 80N0G; 80A0G 4) Surface-flush door handle fails to retract and/or extend The fault code B185911 is stored in the DCU (N69/X). The motor resistance is too low. Bearing bracket must be replaced. Please use one of the following damage codes: 80A0D; 80N0D; 80N0E; 80A0E If after the remedy points above are performed and the problem is still present, then please create a TIPS case and direct to the Body/Chassis/Entertainment inbox. Include your control unit logs, photos/videos, and quick tests to show diagnosis performed thus far. -> In this case, store the damaged parts for further analyses.
NHTSA メーカー資料 ↗メーカー、番号、発行日、全文概要が一致した登録だけをまとめ、元番号を残します。古い資料も保持し、明示的に確認できた後続版を表示します。1994年以前の車両との関連は通常結果から分離します。年式未記載は全年式への適用を意味しません。