表示

JEEP

08-038-26

2026-02-04 · NHTSA 11028756

掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。

メーカー概要

英語の原文

Flash: Battery Pack Control Module (BPCM) Updates **Customers must experience a Malfunction Indicator Lamp (MIL) illumination and the vehicle must SYMPTOM: exhibit/set one or more of the following Diagnostic Trouble Codes (DTCs): ● P0B28-00 - Hybrid/EV Battery “B” Voltage Unstable. ● P0BBE-00 - Hybrid/EV Battery Pack Voltage Variation. ● P0AA1-00 - Hybrid/EV Battery Positive Contactor “A” Stuck Closed. ● P0C78-00 - Hybrid/EV Battery System Precharge Time Too Long. ● P0CA6-00 - Hybrid/EV Battery Charging Current High. ● P0B24-00 - Hybrid/EV Battery "A" Voltage Unstable. ● P1C5E-00 - Hybrid/EV Battery State Of Health Failed. ● P0DAB-00 - Hybrid/EV Cell Balancing Performance. ● P0607-00 - ECU Internal Performance.** **Customers may also comment on the following: ● Vehicle does not start. NOTE: The no start condition is accompanied with the following DTCs: P0DAB-00, P0607-00, P0AA1-00, P0AA4-00, P0C78-00, P0CA6-00, P0B24-00 and/or P1C5E-00. P0B28-00 will result in a MIL for 49 days. After 49 days of the MIL, the vehicle will no longer be allowed to start.** This bulletin involves reprogramming the BPCM with the latest available software. NOTE: Additional module flashes are required for this update to be effective, the following modules

NHTSA メーカー資料 ↗

メーカー、番号、発行日、全文概要が一致した登録だけをまとめ、元番号を残します。古い資料も保持し、明示的に確認できた後続版を表示します。1994年以前の車両との関連は通常結果から分離します。年式未記載は全年式への適用を意味しません。