MERCEDES-BENZ
LI47.70-P-076030
2026-02-24 · NHTSA 11029061
掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。
メーカー概要
英語の原文
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"
NHTSA メーカー資料 ↗メーカー、番号、発行日、全文概要が一致した登録だけをまとめ、元番号を残します。古い資料も保持し、明示的に確認できた後続版を表示します。1994年以前の車両との関連は通常結果から分離します。年式未記載は全年式への適用を意味しません。