表示

MERCEDES-BENZ, MERCEDES-MAYBACH

LI82.85-P-080359

2026-03-19 · NHTSA 11030159

掲載車両は調査の手がかりです。エンジン、製造期間、ソフトウェア条件はメーカー資料で確認してください。

メーカー概要

英語の原文

Complaint Mercedes me connect services inoperative (me-Call, Remote Status, etc.). Mercedes me services - activation not possible Notes: - The event code "B16AC00 - The configuration of the SIM card is erroneous" is active and stored - The head unit shows no internet connection Cause The RAMSES module may be faulty. This fault profile can be recognized as follows: With XENTRY Diagnosis, enter the "ACTUAL values" menu of the RAMSES control unit and read out the values with position 175 and 727. ACTUAL values in the event of a fault: Type of mobile service (position 175): No reception Operating mode (position 727): Ready mode Remedy If B16AC00 is permanently active and saved and position 175 is no reception and position 727 is ready mode, it is highly likely that the communication module is faulty. In this case, an initial start up must be carried out. If the problem persists even after an initial start up, please create a TIPS case.

NHTSA メーカー資料 ↗

メーカー、番号、発行日、全文概要が一致した登録だけをまとめ、元番号を残します。古い資料も保持し、明示的に確認できた後続版を表示します。1994年以前の車両との関連は通常結果から分離します。年式未記載は全年式への適用を意味しません。