MERCEDES-BENZ, MERCEDES-MAYBACH
LI54.10-P-075043
2022-07-18 · NHTSA 10217160
목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.
제조사 요약
영어 원문
Complaint On affected hybrid vehicles of model series 223, a sporadic or continuously displayed red 12V warning message is shown in the instrument cluster. Cause Based on the current status of the analyses, 2 different causes may be considered probable: ·Failure of the current limiter module: The fault does not necessarily trigger a fault code. This fault profile is likely in the event of continuous 12V red messages. ·A second cause of the fault is indicated by the saved fault codes P0E32FA in the HV DC/DC converter (N82/2; see XENTRY Diagnosis for fault code) and, in some cases, B161609 in the electronic ignition switch (N73). This fault profile is likely in the event of sporadic 12V red messages. Remedy For cause analysis, the quick test for the vehicle should be examined for the presence of either of the two fault codes specified above. If no DTCs are saved and a continuous 12V red message is shown in the instrument cluster, the current limiter module is likely faulty and the component part must be replaced. In the event that the fault codes are saved in the DC/DC converter, the guided check must be followed. Depending on the result of the diagnosis, the work must be invoiced to the SSL of the corresponding component part.