보기

MERCEDES-BENZ

LI54.10-P-077250

2024-12-11 · NHTSA 11011846

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사 요약

영어 원문

Complaint Customer states CEL is on. Cause Quick test shows FC P0A7F00 The state of health limit of the hybrid/high-voltage battery module has been reached. No drivability concerns occurred and vehicle drives as normal. Remedy Do not replace any parts!! 254: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 51 75 MY24 206: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 52 75 After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.

NHTSA 제조사 자료 ↗

제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.