보기

MERCEDES-BENZ, MERCEDES-MAYBACH

LI83.30-P-079081

2025-04-21 · NHTSA 11017217

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사 요약

영어 원문

Complaint Random heating of air conditioning system. Cause Temperature sensor in overhead control panel (OCP) delivering incorrect values: The temperature sensor in the overhead control panel is malfunctioning. Fault code B110709 or fault code B11F697 are present in the overhead control panel with the status (active) or (active stored). or The temperature sensor in the overhead control panel measures an incorrect temperature (the temperature value can be checked against the actual value in the overhead control panel) If the above-mentioned fault code is not present, the cause could be malfunction on the air conditioning system. Remedy If one of the above-mentioned fault codes should occur, a TIPS case must be created here. If the above fault codes or actual value differences are present in the OCP - please send the case to the Body/Chassis/ Entertainment inbox. Otherwise, the case must be sent to the HV/LV inbox for support in A/C diagnosis. *** It is not necessary to replace the overhead control panel ***

NHTSA 제조사 자료 ↗

제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.