영어 원문
Complaint AC charging is not possible. Charging is interrupted after 15 minutes. Following malfunctions on Instrument Cluster (IC) can appear : • "AC charging inoperative Consult workshop" • "Performance severely limited “Hybrid drive system” The following fault codes related to the failure can be found in the below Control units : PTCU - N127 (Drivetrain control unit) • P0667FA - On-board charger • P0F7FFA - On-board charger OBL223_GEN4 - N83/11 (Alternating current charger for high-voltage battery): • P0667FA - The internal temperature sensor of the control unit has a malfunction. • P0F7FFA - The signals of coolant temperature sensors 1 and 2 of the on-board charger are implausible in comparison with each other. • P0D8F97 - The cooling of the on-board charger is inadequate. The system function is restricted. INV1G40 - N147 (Power electronics control unit): • P0A9300 - The cooling system for the low temperature circuit has a malfunction Cause • The coolant lines of the LT1 (low temperature) cooling circuit for the power electronics (N147) and the LT2 (low temperature) cooling circuit for the AC charger (OBL), may have been installed in reverse order Remedy • It is possible that the coolant hoses highlighted in the pictures are installed in reverse order. • Interchange these two coolant lines and check if the vehicle is charging without any malfunction.
NHTSA 제조사 자료 ↗제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.