MERCEDES-BENZ, MERCEDES-MAYBACH
LI80.20-P-078308
2026-02-27 · NHTSA 11029090
목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.
제조사 요약
영어 원문
Complaint Please perform the corresponding remedy measures (points 1-4) depending on the determined problem (points 1-4): 1. KeylessGo sensor surfaces do not respond. Door handles can extend/retract if unlocked/locked using the key. No particular fault code. 2. Flush-fitting door handle does not extend and/or retract. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_bridge_connection_fatal_error = True OR Motor_bridge_wrong_direction_fatal_error = True (see attachment for example) 3. Flush-fitting door handle does not extend and/or retract. One or more of the following fault codes are current and stored: B185D96; B185E96; B186196; B186296 The following values are present in the control unit log (A17/x): Motor_init_error_for_sensors = True (for example, see attachment) 4. Flush-fitting door handle does not extend and/or retract. The fault code B185911 is stored in the DCU (N69/X). Cause 1. Software bug. 2. Software robustness. 3. Software robustness. 4. The resistance of the motor is outside of tolerance. Remedy Please perform the corresponding remedy measures (points 1-4) depending on the determined problem (points 1-4): 1. Perform a reset of the corresponding 'KEYLESS GO' door handle control unit (A17/x) via XENTRY (for example see attachment) add-on is available (add-on 32204 for XENTRY version 06/25) Please use one of the following damage codes: 8213H73; 8219773; 8213K73; 8219873 2. A control unit event log for the component part concerned (A17/x) must be created and the following values checked in the "Component Errors" section: Motor_bridge_connection_fatal_error = True (for example, see attachment) OR Motor_bridge_wrong_direction_fatal_error = True (for example, see attachment) If one of the values is "True": Perform an SCN coding on the corresponding 'KEYLESS GO' door handle control unit (A17/x) via XENTRY add-on is available (add-on 32280 for XENTRY version 06/25) The faults must be deleted after SCN coding. Please use one of the following damage codes: 8213H73; 8219773; 8213K73; 8219873 3. A control unit event log for the component part concerned (A17/x) must be created and the following value checked in the "Component Errors" section: Motor_init_error_for_sensors = True (for example, see attachment) If the value is "True": Bearing bracket must be replaced. Please use one of the following damage codes: 80A0D73; 80N0D73; 80N0E73; 80A0E73 4. The motor resistance is too low. Bearing bracket must be replaced. Please use one of the following damage codes: 80A0D73; 80N0D73; 80N0E73; 80A0E73 Please note that other published GI documents may also be valid for assessing the problem. For example: "LI72.10-P-074316 Flush-Mounted Door Handle Jams When It Is Pulled Out". If after the remedy points above are performed, the problem is still present, please submit a TIPS case to the PTS-Body/ Chassis/Entertainment inbox. → In this case, store the damaged parts for further analyses.
NHTSA 제조사 자료 ↗제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.