보기

MERCEDES-BENZ, MERCEDES-MAYBACH

LI54.10-P-080602

2026-05-20 · NHTSA 11032890

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사 요약

영어 원문

Complaint 48V battery (A66) part numbers A 000 982 78 24, A 000 982 57 30, A 000 982 88 31, A 000 982 50 32, A 000 982 87 32) may trigger a fault message ("48 V Service Required" with fault codes P0ADA91, P0ADE91, P0AA100, P0ADD00 or P0AA000) in the instrument cluster. This fault message may prevent the 48 V battery contactors from opening automatically if the 12 V power supply is interrupted. In this case, the 48 V on-board electrical system, including connected components, remain energized. Cause The contactors of the 48 V battery do not open, resulting in residual voltage (> 3V) even when the 12 V battery is disconnected. Remedy When working on the 48 V on-board electrical system or connected components, ensure the component being repaired is de-energized in the 48 V system after disconnecting the 12 V ground line. Use a DVOM and ensure that there is less than 3V across the 48V terminals. • If the voltage is less than 3V, the repair can be continued in accordance with the WIS documentation. • If the voltage is greater than 3V, disconnect the ground line from the 48 V on-board electrical system battery and secure from contacting any ground points of the vehicle before continuing the repair. Once the work has been completed, follow the procedure for clearing the 48 V battery fault message as specified.

NHTSA 제조사 자료 ↗

제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.