보기

FREIGHTLINER, MERCEDES-BENZ

LI09.41-N-080666

2026-06-03 · NHTSA 11034415

목록의 차량은 조사 단서입니다. 제조사 자료에서 엔진, 생산 기간, 소프트웨어 조건을 확인하세요.

제조사 요약

영어 원문

Check engine light with reduced power –P300A6D due to charge air system contamination Complaint The check engine light is activated, accompanied by fault code 'P300A6D The boost pressure is too low', indicating reduced boost pressure. Cause Charge air system restriction due to contamination: • Oil mist from the crankcase ventilation system can enter the intake tract and deposit within the charge air system • Under high thermal load and with soot-laden or aged engine oil, these deposits may carbonize • Carbonized deposits can loosen and accumulate in the charge air cooler and related components • This can result in partial or complete restriction of the charge air cooler, leading to underboost conditions and fault codes such as P300A6D Contributing factors may include: • High engine load operating profiles • Extended oil service intervals or degraded engine oil condition Remedy Prerequisite: Complete all guided diagnostic test steps for fault code P300A6D in Xentry Diagnostics and follow LI09.40-N-079144 before performing the repairs below. If carbonized oil deposits or restriction are identified within the charge air system: 1. Replace the following components as a set: • Charge air cooler • Exhaust turbocharger • Charge air pipe upstream of the charge air cooler 2. After completing repairs: • Perform engine oil and filter replacement using an approved specification oil. Approved oil specifications: • MB 229.52 SAE 5W-30 - BB00.40-P-0229-52A • MB 229.51 SAE 5W-30 - BB00.40-P-0229-51A 3. Perform control unit adaptations: • Reset intake air system adaptation values • Reset low-pressure exhaust gas recirculation (EGR) adaptation values 4. After repair completion: • Perform a test drive • Verify that the fault code does not return 5. If the vehicle is within warranty and the charge air cooler is determined to be obstructed by debris, use damage code 50301 B2 when submitting the warranty claim. Notes: • Additional component replacement is not required unless supported by further diagnostic results. • Do not replace the charge air distributor pipe or Clean Air Line unless additional faults (for example, air mass-related faults) are present. • After replacement of components, ensure proper initialization and learning procedures are completed in the control unit. • Creation of an XENTRY TIPS case is not required for this condition. • Please review the attached photos for previously identified causes of these fault codes.

NHTSA 제조사 자료 ↗

제조사, 번호, 발행일, 전체 요약이 같은 등록만 묶고 원래 번호를 보존합니다. 과거 자료도 유지하며 확인된 명시적 후속판만 표시합니다. 1994년 이전 관계는 기본 결과와 분리합니다. 연식 미기재는 모든 연식 적용이 아닙니다.