Mazda P1632 | Smart generator malfunctions sensor/circuit |
---|---|
DETECTION CONDITION
|
• Generator pulse width modulation input – Signal error
|
POSSIBLE CAUSE
|
• Generator malfunction
• PCM malfunction
|
Diagnostic procedure
STEP | INSPECTION | ACTION | |
---|---|---|---|
1
|
VERIFY FREEZE FRAME DATA HAS BEEN RECORDED
• Has the FREEZE FRAME DATA been recorded?
|
Yes
|
Go to the next step.
|
No
|
Record the FREEZE FRAME DATA on the repair order, then go to the next step.
|
||
2
|
VERIFY RELATED REPAIR INFORMATION AVAILABILITY
• Verify related service repair information availability.
• Is any related repair information available?
|
Yes
|
Perform repair or diagnosis according to the available repair information.
• If the vehicle is not repaired, go to the next step.
|
No
|
Go to the next step.
|
||
3
|
VERIFY CURRENT SIGNAL STATUS: IS CONCERN INTERMITTENT OR CONSTANT?
• Connect the M-MDS to the DLC-2.
• Clear the DTC from the PCM memory using the M-MDS.
• Run the vehicle under the FREEZE FRAME DATA stored condition.
• Is the same DTC present?
|
Yes
|
Go to the next step.
|
No
|
Intermittent concern exists.
Perform the “INTERMITTENT CONCERNS TROUBLESHOOTING”.
|
||
4
|
INSPECT GENERATOR
• Inspect the generator.
• Is there any malfunction?
|
Yes
|
Replace the generator, then go to the next step.
|
No
|
Go to the next step.
|
||
5
|
VERIFY THAT DTC P1632 TROUBLESHOOTING IS COMPLETED
• Make sure to reconnect all connectors.
• Clear DTC from PCM memory using M-MDS.
• Run the vehicle under the FREEZE FRAME DATA stored condition.
• Is the same DTC present?
|
Yes
|
Replace PCM, then go to the next step.
|
No
|
Go to the next step.
|
||
6
|
VERIFY AFTER REPAIR PROCEDURE
• Perform the after repair procedure.
• Are any DTCs present?
|
Yes
|
Go to the applicable DTC inspection.
|
No
|
DTC troubleshooting completed.
|