P0372 Audi Timing Reference High Resolution Signal A Too Few Pulses

P0372 Audi Timing Reference High Resolution Signal A Too Few Pulses

Possible causes
– Timing Reference Optical Sensor harness is open or shorted
– Timing Reference Optical Sensor circuit poor electrical connection
– Faulty Timing Reference Optical Sensor
– Damaged Powertrain Control Module (PCM)
What about the obd code?
Some high resolution pulses are missing from the optical sensor to the PCM
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
P0372 Audi Description

The optical sensor provides a high resolution signal to the Powertrain Control Module (PCM) by counting pulses on the sensor disk located in the injection pump. The high resolution is one of the most important inputs by the PCM for fuel control and timing. This test monitors the number of high resolution pulses which have been missed (not detected). It’s based on a comparison between the number of pulses that were detected since the last pump cam pulse and the number of the pulses that should have occurred. There are approximately 64 high resolution pulses for every cam pulse.

Audi Vehicle:Audi A1,Audi A3,Audi A1,Audi A3,Audi A1,Audi A3,Audi A4,Audi A5,Audi Q3,Audi A5,Audi Q5,Audi A3,Audi A4,Audi A5,Audi TT,Audi Q3,Audi Q5,Audi S3,Audi TTS,Audi RS 3,Audi TT RS,Audi A7,Audi Q7,Audi A8,Audi A6,Audi S4,Audi S5,Audi Q5,Audi S6,Audi S8,Audi S5,Audi A8,Audi R8 V8,Audi RS 5,Audi S6,Audi R8 V10,Audi R8 GT,Audi A8L