P1167 Cadillac Heated Rear Oxygen Sensor 2 Maximum Voltage Monitoring Bank 2

P1167 Cadillac Heated Rear Oxygen Sensor 2 Maximum Voltage Monitoring Bank 2

Possible causes
– Faulty Heated Rear Oxygen Sensor Bank 2
– Heated Rear Oxygen Sensor Bank 2 harness is open or shorted
– Heated Rear Oxygen Sensor Bank 2 circuit poor electrical connection
– Fuel pressure
– Injectors
– Intake air leaks
Tech description
Replacing the Rear Oxygen (O2) Sensor usually takes care of the problem
What about the obd code?
The P1167 Cadillac code is triggered when the maximum voltage from the sensor is not reached to the specified voltage.
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
– Possible high fuel consumption
– Possible excessive smoke from exhaust
P1167 Cadillac Description

The heated oxygen sensor 2 (rear), after three way catalyst, monitors the oxygen level in the exhaust gas on each bank. Even if switching characteristics of the heated oxygen sensor 1 (front) are shifted, the air fuel ratio is controlled to stoichiometric, by the signal from the heated oxygen sensor 2. This sensor is made of ceramic zirconia. The zirconia generates voltage from approximately 1V in richer conditions to 0V in leaner conditions. Under normal conditions the heated oxygen sensor 2 is not used for engine control operation.

Cadillac Vehicle:Cadillac CTS Coupe, Cadillac CTS-V Coupe , Cadillac Eldorado , Cadillac Escalade EXT , Cadillac ATS , Cadillac CTS , Cadillac CTS Sedan , Cadillac CTS Sport Sedan , Cadillac CTS-V , Cadillac CTS-V Sedan , Cadillac Catera , Cadillac DTS , Cadillac DeVille , Cadillac STS-V , Cadillac STS , Cadillac Seville , Cadillac XTS , Cadillac XLR , Cadillac XLR Platinum , Cadillac Escalade , Cadillac SRX