P1402 Ford EGR Function Open

P1402 Ford EGR Function Open

Possible causes
– The EGR volume control valve circuit harness is open or shorted
– EGR volume control valve leaking or stuck open
– Faulty EGR temperature sensor
Tech description
Start by cleaning the EGR valve, if the code persist it may be necessary to replaced the EGR Valve
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
P1402 Ford Description

This system controls flow rate ofEGR led from exhaust manifold to intake manifold. The opening of the EGR by-pass passage in theEGR volume control valve changes to control the flow rate. A built-in step motor moves the valve in steps corresponding to the ECM output pulses. The opening of the valve varies for optimum engine control. The optimum value stored in the ECM is determined by considering various engine conditions. The EGR volume control valve remains closed under the following conditions.

– Engine stopped

– Engine starting

– Engine idling

– Low engine coolant temperature

– Excessively high engine coolant temperature

– High engine speed

– Wide open throttle

– Low battery voltage

Ford Vehicle:Ford Escape,Ford Focus Flexifuel,Ford Mustang,Ford Fusion,Ford Taurus,Ford F-Series,Ford Explorer,Ford C-Max,Ford Escape,Ford Edge,Ford Explorer,Ford Flex,Ford Expedition,Ford Transit Connect,Ford F1-50,Ford E-Series Wagon,Ford Super Duty,Ford Fusion Hybrid SE,Ford C-MAX Hybrid SEL,Ford C-MAX Energi,Ford Fusion Energi SE,Ford Fucos Electric,Ford E-Series Van,Ford E-Series Cutaway,Ford Super Duty Pick Up,Ford Chassis Cab,Ford F-650/F-750,Ford Stripped Chassis