P2271 Isuzu HO2S Signal Stuck Rich Bank 1 Sensor 2

P2271 Isuzu HO2S Signal Stuck Rich Bank 1 Sensor 2

Possible causes
– Faulty Rear Heated Oxygen Sensor Bank 1
– Rear Heated Oxygen Sensor Bank 1 harness is open or shorted
– Rear Heated Oxygen Sensor Bank 1 circuit poor electrical connection
– Intake air leaks
– Exhaust gas leaks
– Inappropriate fuel pressure
– Faulty fuel injectors
What about the obd code?
The Powertrain Control Module (PCM) detected the HO2S12 sensor has reported a rich condition for an extended period during an intrusive test
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
– High Fuel Consumption
– Excessive Smoke from Exhaust
P2271 Isuzu Description

The Powertrain Control Module (PCM) supplies a voltage of about 450 mV between the HO2S high and low signal circuits. The oxygen sensor varies the voltage over a range from about 1,000 mV when the exhaust is rich, down through about 10 mV when the exhaust is lean.

The PCM monitors and stores the heated oxygen sensor (HO2S) voltage information. The PCM evaluates the HO2S voltage samples in order to determine the amount of time the HO2S voltage was out of range. The PCM compares the stored HO2S voltage samples taken within each sample period and determines if majority of the samples are out of the operating range.

Isuzu Vehicle:2013 Isuzu,2012 Isuzu,2011 Isuzu,2010 Isuzu,2009 Isuzu,2008 Isuzu,2007 Isuzu,2006 Isuzu,2005 Isuzu,2004 Isuzu,2003 Isuzu,2002 Isuzu,2001 Isuzu,2000 Isuzu,1999 Isuzu,1998 Isuzu,1997 Isuzu,1996 Isuzu,Isuzu Rodeo,Isuzu Trooper,Isuzu Ascender