P2402 Volvo Evaporative Emission (EVAP) System Leak Detection Pump Control Circuit High

P2402 Volvo Evaporative Emission (EVAP) System Leak Detection Pump Control Circuit High

Possible causes
– Faulty Vacuum Pump Module
– Vacuum Pump Module harness is open or shorted
– Vacuum Pump Module circuit poor electrical connection.
– Faulty Engine Control Module (ECM)
Tech description
What about the obd code?
To determine leak criterion (Reference pressure), vacuum pump creates negative pressure in canister pump module through 0.02 inch orifice and pressure is measured. If the conditions are not met, Engine Control Module (ECM) the code will be set.
Symptoms
– Engine Light ON (or Service Engine Soon Warning Light)
P2402 Volvo Description

5 hours* after the ignition switch is turned OFF, the electric vacuum pump creates negative pressure (vacuum) in the EVAP (Evaporative Emission) system. The Engine Control Module (ECM) monitors for leaks and actuator malfunctions based on the EVAP pressure.

Volvo Vehicle:Volvo C70,Volvo S40,Volvo XC90,Volvo XC70,Volvo XC60,Volvo V70,Volvo V50,Volvo V40,Volvo S90,Volvo S80,Volvo S60
CategoriesUncategorized