MERCEDES-BENZ
LI54.10-P-077250
2024-12-11 · NHTSA 11011846
A relação com um veículo é uma pista. Confirme motor, produção e software na documentação do fabricante.
Resumo do fabricante
Texto original em inglês
Complaint Customer states CEL is on. Cause Quick test shows FC P0A7F00 The state of health limit of the hybrid/high-voltage battery module has been reached. No drivability concerns occurred and vehicle drives as normal. Remedy Do not replace any parts!! 254: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 51 75 MY24 206: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 52 75 After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.
Comunicados da NHTSA ↗Só agrupamos registros com fabricante, número, data e resumo completo iguais. Mantemos identificadores e documentos antigos; sinalizamos substituições explícitas confirmadas. Relações anteriores a 1994 ficam separadas dos resultados padrão. Ano não informado não significa todos os anos.