Смотреть

MERCEDES-BENZ

LI47.70-P-076030

2026-02-24 · NHTSA 11029061

Связь с автомобилем — отправная точка. Уточняйте двигатель, период выпуска и ПО по данным производителя.

Аннотация производителя

Оригинал на английском

Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The fault message and the fault memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For plug-in Model Series167, 206, 214, 223, 247, 254: Carry out software update and SCN coding for the control unit "N83 – AC charger for high-voltage battery (SG-LG)". For model series 243: Carry out software update and SCN coding for the control units "N116/5 – DC charge-connection unit (DCCU)" and "N83/11 – AC charger for high-voltage battery (SG-LG)"

Материалы NHTSA ↗

Группируются только записи с одинаковыми маркой, номером, датой и полным текстом аннотации. Номера и старые документы сохраняются; отмечаются установленные явные замены. Автомобили до 1994 года отделены от обычных результатов. Неуказанный год не означает все годы.