查看

MERCEDES-BENZ

LI54.10-P-069698

2021-02-19 · NHTSA 10189404

车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。

厂商摘要

以下为英文原文

Complaint: Various causes are possible. The faults listed in the various causes do not all have to be present at all times. Some of these complaints may overlap. Rely on the faults listed in the Cause section for identifying the correct Remedy. 1. No start 2. Yellow or red instrument cluster message for 48 V on-board electrical system battery (G1/3) 3. Limp home mode, overheating, A/C not blowing cold, or loss of acceleration Cause: Cause 1: Software causes intermittent no starts with fault B183387 in DC/DC converter N83/1 Cause 2: Software causes Permanent no starts with fault B183349 and B183371 in 48V battery G1/3. Cause 3: Hardware short circuit in 48V system causes fault B183319 in 48V battery Cause 4: 48V battery detects abnormality and disconnects causing additional symptoms: Limp Home Mode, overheating, A/C not blowing cold, or loss of acceleration This cause will always have fault code in G1/3: B183371 but will Not have B183349. Remedy: Note: each of these remedies correspond to a specific cause. Make sure to match correct Cause with Remedy. Remedy 1: Update software in G1/3 (48V battery) using newest Xentry software and AddOns Remedy 2: 1. Check software version in 48V battery via quick test. If 19/46 000 replace only 48V battery (regardless of other faults)

NHTSA 厂商通报资料 ↗

仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。