Bentayga Hybrid - Unable to charge the high voltage battery or charging starts and then stops. Customer statement: Unable to charge the high voltage battery, or charging starts and then stops. Workshop findings: The following DTCs are evident within the high voltage battery charger control module (Diagnostic address C6) - P33EC00: External plug in charge socket A electrical error - P31CB00: Immediate upload button Stuck Closed - P168F00: System malfunction And/or The following DTC is evident within hybrid battery management control module (Diagnostic address 8C) - P0E5E00: Battery charger control module processor performance. Measure: 1) Referring to Rep.Gr 93 - Carry out an Inspection and classification of the Hybrid battery unit AX1