MERCEDES-BENZ, MERCEDES-MAYBACH
LI47.70-P-078563
2024-11-04 · NHTSA 11010435
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。
厂商摘要
以下为英文原文
Complaint -Check engine light(MIL) is ON. -Current and stored fault code in DCCU and PTCU : P2E9873 The position sensor of the exterior socket flap of the vehicle socket (direct current) has an electrical fault. The actuator does not open. -Starting the vehicle or Charging the vehicle is normal without any issues. Cause Software in the "N116/5 - Direct current charge connection unit (DCCU)" control unit. Remedy SW remedy for N116/5(DC-Charging control unit box) is in progress. Once the software is available, update the software for N116/5 and perform SCN coding of N116/5 For this issue, the vehicle starting or charging functions are not typically affected. Do not replace any parts. Replacing parts will not bring a solution for this issue.
NHTSA 厂商通报资料 ↗仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。