MERCEDES-BENZ, MERCEDES-MAYBACH
LI54.10-P-077250
2025-01-07 · NHTSA 11012782
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。
厂商摘要
以下为英文原文
Complaint For the potentially affected vehicles, excessively high aging of the battery was calculated at cold battery temperatures (<50°F) and the MIL activated accordingly, even though there is no corresponding high level of aging physically. In this regard, the fault code P0A7F00 "The age limit of the hybrid/high-voltage battery module has been reached" is displayed in the N127 PTCU control unit and/or A66 battery module control unit (48 V battery). Cause Faulty computation of the age limit of the 48 V battery. Remedy Do not replace any parts!! Step 1: Perform the software update of A66 battery module (48 V battery) After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.
NHTSA 厂商通报资料 ↗仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。