MERCEDES-BENZ
LI47.70-P-076030
2026-02-05 · NHTSA 11028610
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。
厂商摘要
以下为英文原文
Complaint After the charging process is complete, an instrument cluster message with a charging error appears and FC P0CFE00 is stored in control unit "N83 - AC charger for high-voltage battery (SG-LG)". The instrument cluster message and the FC memory entry can also appear at the beginning of the charging pause during delayed charging. Both only occur in combination with active pre-entry climate control. Cause Software in control unit "N83 - AC charger for high-voltage battery (SG-LG)". Remedy For model series 206 and 223 with code 802: Perform a software update and SCN coding for the control unit "N83/11 - AC charger for high-voltage battery (SGLG)" in order to remedy the problem. For model series 243: The correction is already available. Perform a software update and SCN coding for the control units "N116/5 - Direct current charging connection unit (DCCU)" and "N83/11 - AC charger for high-voltage battery (SG-LG)" in order to remedy the problem.
NHTSA 厂商通报资料 ↗仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。