查看

MERCEDES-BENZ, MERCEDES-MAYBACH

LI82.85-P-080507

2026-05-26 · NHTSA 11033185

车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。

厂商摘要

以下为英文原文

Complaint After successful commissioning of the HERMES control unit (N112/9) with XENTRY Diagnosis DVD 03/2026, the message "SOS - service not activated" appears on the instrument cluster. In addition, the following two conditions are also met: • HERMES (N112/9) control unit: event code B15CE00 is ACTIVE and STORED (A+S) • Vehicle Documentation System: For the HERMES control unit, the EID1, EID2, ICCID, IMEI, IMSI, TELNR fields in the "Identification/Serial number" column have the value "-" Cause Still under analysis Remedy Recommission the HERMES control unit (N112/9) with XENTRY Diagnosis 03/2026 and add-on 33399 installed or carry out the procedure with a newer version of XENTRY Diagnosis: XENTRY→ "N112/9 - Control unit for telematics services (HERMES)" -> "Adaptations" -> "Control unit commissioning" -> "Commissioning of previously installed control unit"

NHTSA 厂商通报资料 ↗

仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。