MERCEDES-BENZ
LI27.19-P-080869
2026-08-29 · NHTSA 11037210
车型关联可作为查阅线索;具体发动机、生产范围和软件条件请核对厂商资料。
厂商摘要
以下为英文原文
Complaint Temporary no start condition with check engine light and multiple warning messages. When performing a quick test, the following fault code is stored in Y3/14 ‐ Transmission control for 8‐speed dual‐clutch transmission (DKG): P24F100 The wake‐up line of the control unit has a short circuit to positive. Cause Possible signal timing between EZS control unit and Transmission Control Unit (DKG) Remedy As of 7/15/2026, new SCN coding is available for the EZS control unit. IPR will advise to open a TIPS case for EZS (N73), this is due to GLA models requiring support for SCN coding procedure. GLB (X247) and CLA (118) No TIPS case necessary. 1. SCN coding of EZS Control Unit 2. Clear all faults and perform extended road test with multiple drive cycles GLA (H247) Special function password required. 1. Verify if special procedure Central Locking ‐ Development Data is present in EZS (figure 1) 2. Submit a TIPS case to the Powertrain Inbox with the following information: ‐ Initial Quick Test w/ freeze frame data ‐ IPR Result ‐ DKG Control Unit Log ‐ EZS Control Unit Log ‐ Initial EEPROM data ‐ EZS special procedure menu If the vehicle has had this LI performed and P24F100 has returned, please submit a TIPS case to the Powertrain Inbox.
NHTSA 厂商通报资料 ↗仅当厂商、通报编号、发布日期和完整摘要一致时,重复登记才会合并展示,原始编号仍予保留。旧资料继续供查阅;确认明确替代关系后才标示后续版本。1994 年以前的车辆关联与默认结果分开显示;未注明年款不等于适用于所有年款。