LI54.10-P-080684 ↗

MERCEDES-BENZ · 2026-09-17

Complaint When disconnecting or connecting the charging connector, the charging socket flashes red and red warning messages are displayed in the instrument cluster. Immediately after that, neither driving nor charging is possible. Cause P292900: Contact 'Negative terminal' of contactor B in the high‐voltage battery is jammed closed If the charging cable connector is removed approximately 5 to 7 seconds after the charging process has ended, a fault is triggered. Remedy If this fault occurs, please follow these steps: 1) Wait for bus idle ‐> driving should be possible again. Note: Charging is still not possible. The fault will keep recurring as long as the fault is stored in the fault memory. 2) Plug in charging cable and check if fault (P292900 or P0AE173) is active. Clear active fault.…

LI54.10-P-080684 ↗

MERCEDES-BENZ · 2026-08-06

Complaint When disconnecting or connecting the charging connector, the charging socket flashes red and red warning messages are displayed in the instrument cluster. Immediately after that, neither driving nor charging is possible. Cause P292900: If the charging cable connector is removed approximately 5 to 7 seconds after the charging process has ended, a fault is triggered. Remedy If this fault occurs, please follow these steps: 1) Wait for bus idle -> driving should be possible again. Note: Charging is still not possible. The fault will keep recurring as long as the fault is stored in the fault memory. 2) Plug in charging cable and check if fault (P292900 or P0AE173) is active. Clear active fault. Charging should be possible after the fault has been cleared. To prevent the fault from…

B20-021 ↗

ACURA · 2020-12-18

"Service Bulletin - The motor power inverter (MPI), also known as the intelligent inverter unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter…

A20-030 ↗

HONDA · 2020-12-18

"Service Bulletin - The Motor Power Inverter (MPI), also known as the Intelligent Inverter Unit (IIU), may fail over time due to a defective solder joint. This failure may result in one or more of the following DTC(s): -P1440 (MPI Module Output Circuit Malfunction) -P1437 (MPI Module Short Circuit) -P15A5 (Motor Current Sensor Circuit Malfunction) -P0A78 (MPI Module Internal Circuit Malfunction) -P0AE1 (Bypass Contractor Malfunction) -P0A3C (Motor Control Module (MCM) Overheating) -P0A3F (Motor Rotor Position Sensor Circuit Malfunction) -P0DA8 (MPI Module Voltage Malfunction) -P1634 (MPI Module Signal Circuit Malfunction) -P0AEE (MPI Internal Circuit Malfunction) -P0A27 (High Voltage Contactor Stays Activated) American Honda is extending the warranty coverage of the motor power inverter…