LI47-70-N-080294 ↗

MERCEDES-BENZ · 2026-03-03

eSprinter model series 907: Intermittent no-start condition Complaint Intermittent no-start condition; partial restart without "Ready" status in display. Concern may be rectified after bus idle and/or circuit 30 deep reset. Cause As a result of inaccuracies in Battery Management System measurements, the BMS may record the following fault codes: P0ABD00 - Battery voltage sensor A in the hybrid/high-voltage battery module has a short circuit to positive. P0B171C - Battery voltage sensor B in the hybrid/high-voltage battery module has a short circuit to positive. The vol-tage value is outside the permissible range P181D12 - The reference voltage at output A has exceeded the limit value. There is a short circuit to positive Remedy Perform a software update of control unit G1/9 - battery…