查看

MERCEDES-BENZ

LI14.30-N-075882

2023-02-03 · NHTSA 10232325

車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。

原廠摘要

以下為英文原文

Complaint Check engine warning light active. Fault code P300CA8 or P300CA9 "Hot film mass air flow sensor malfunction" is present in engine control unit. Cause a) In the case of fault P300CA8: • Due to incorrectly installed component parts of the clean air line between the air filter box and the exhaust gas turbocharger, it is possible that leaks may occur in the system which subsequently result in air mass faults • A fouled air filter or leaks in the intake or charge air system downstream of the exhaust gas turbocharger may also cause these faults. b) In the case of fault P300CA9: • Computational model for programmed values of air intake, in particular, for the high load mode, calculates this high load correction programmed value incorrectly. This leads to the programmed value drifting too quickly towards the limit. Remedy Install the following add-ons: 18937 for XENTRY 12/2020 18938 for XENTRY 03/2021

NHTSA 原廠通報資料 ↗

僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。