MERCEDES-BENZ
LI54.10-P-077250
2024-12-11 · NHTSA 11011846
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
原廠摘要
以下為英文原文
Complaint Customer states CEL is on. Cause Quick test shows FC P0A7F00 The state of health limit of the hybrid/high-voltage battery module has been reached. No drivability concerns occurred and vehicle drives as normal. Remedy Do not replace any parts!! 254: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 51 75 MY24 206: SW has been released. Ensure all Add-ons are installed. Update A66 with the latest SW A 000 903 52 75 After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.
NHTSA 原廠通報資料 ↗僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。