查看

MERCEDES-BENZ, MERCEDES-MAYBACH

LI54.10-P-077250

2025-01-29 · NHTSA 11013190

車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。

原廠摘要

以下為英文原文

Complaint For the potentially affected vehicles, excessively high aging of the battery was calculated at cold battery temperatures (<50°F) and the MIL activated accordingly, even though there is no corresponding high level of aging physically. In this regard, the fault code P0A7F00 "The age limit of the hybrid/high-voltage battery module has been reached" is displayed in the N127 PTCU control unit and/or A66 battery module control unit (48 V battery). Cause Faulty computation of the age limit of the 48 V battery. Remedy Do not replace any parts!! Step 1: Perform the software update of A66 battery module (48 V battery) After SW has been updated, perform the following reset procedure: Step 1: Read the State of Health Resistance - (SOH-R) Step 2: If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Drive for a duration of 60 minutes to retrain the SOH-R value. Step 3: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH > 125%: Park vehicle in Workshop for >12 hours in warm ambient temperature >60F, afterwards drive for a duration of 60 minutes. Step 4: Read the State of Health Resistance - (SOH-R) If SOH-R <=125%: Clear fault memory in PTCU(N127) and 48V battery (A66). Procedure finished. If SOH-R is still >125%, open a TIPS case.

NHTSA 原廠通報資料 ↗

僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。