MERCEDES-BENZ
LI47.70-N-079913
2025-11-12 · NHTSA 11026052
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
原廠摘要
以下為英文原文
Vehicle not starting after DC charging Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit) • P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit. • P154A00 - There is a warning due to a detected crash event at standstill. • P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit) • P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal. • P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed • P2BCC00 - The contact ''Negative terminal'' of the contactor in the on-board DC current charge-connection unit is jammed closed. Remedy • Check for a new software availability for DCCU (N24/6 - Direct Current Charge connection Unit). If a new software is available, update the software first. • Reset contactor fault through special procedure without password. ( N24/6 >> Special Procedure >> Resetting of contactor fault.)
NHTSA 原廠通報資料 ↗僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。