查看

MAZDA

SA-030-26

2026-04-22 · NHTSA 11032023

車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。

原廠摘要

以下為英文原文

DESCRIPTION Some vehicles may experience one or more of the following DTCs with the Hybrid system warning light on. This may be caused by an issue with the sub battery located under the passenger floor. P143B Backup power supply system: Sub battery power supply low input. • U3008:01 BPS Backup power supply unit input/output circuit over-current/voltage malfunction. • U3003:17 BPS The output voltage sensor in the backup power supply unit detects that the voltage is standard or more. • U04C0:00 PCM Backup power supply unit internal malfunction. • REPAIR PROCEDURE 1. Remove the sub battery according to the instructions on MGSS. CX-90 (LEAD ACID BATTERY (SUB) REMOVAL/INSTALLATION) • CX-70 (LEAD ACID BATTERY (SUB) REMOVAL/INSTALLATION) • 2. Test the battery's voltage using a digital voltmeter (DVOM) and record the result on the warranty claim. NOTE: The DCA 8000 does not accurately test this small battery. You DO NOT need the DCA 8000 test printout for a warranty claim. 3. Install a new sub battery.

NHTSA 原廠通報資料 ↗

僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。