MERCEDES-BENZ, MERCEDES-MAYBACH
LI82.85-P-080507
2026-05-26 · NHTSA 11033185
車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。
原廠摘要
以下為英文原文
Complaint After successful commissioning of the HERMES control unit (N112/9) with XENTRY Diagnosis DVD 03/2026, the message "SOS - service not activated" appears on the instrument cluster. In addition, the following two conditions are also met: • HERMES (N112/9) control unit: event code B15CE00 is ACTIVE and STORED (A+S) • Vehicle Documentation System: For the HERMES control unit, the EID1, EID2, ICCID, IMEI, IMSI, TELNR fields in the "Identification/Serial number" column have the value "-" Cause Still under analysis Remedy Recommission the HERMES control unit (N112/9) with XENTRY Diagnosis 03/2026 and add-on 33399 installed or carry out the procedure with a newer version of XENTRY Diagnosis: XENTRY→ "N112/9 - Control unit for telematics services (HERMES)" -> "Adaptations" -> "Control unit commissioning" -> "Commissioning of previously installed control unit"
NHTSA 原廠通報資料 ↗僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。