以下為英文原文
Complaint Customers may report one or more of the following: • Transmission malfunction message • Check engine light illuminated • Shifts into N • Concern disappears after ignition cycle When performing a quick test, the following fault code is stored in Y3/14 ‐ Transmission control for 8‐speed dual‐clutch transmission (DKG): P056300 The on‐board power supply voltage is too high. Cause An overvoltage condition is detected exclusively within the transmission control unit, storing fault P056300 once the measured voltage exceeds 16V. Remedy This LI applies if the freeze frame data for P056300 show a supply voltage between 15.75 to 16.50 volts, and no other control units report overvoltage. (figure 1) Long Term Resolution: Software resolutions have been released. Check validity and ensure your Xentry is updated with latest Addons before continuing: 1. Perform software update for Y3/14 ‐ Transmission control for 8‐speed dualclutch transmission (DKG) available software listed in Parts 2. Clear fault memory and perform final test drive If the customer complaint matches this LI and the software currently installed on the vehicle is not listed, please submit a TIPS case to the Powertrain inbox with the following information: ‐ Initial Quick Test w/ Freeze Frame Data ‐ DKG Control Unit Log ‐ Latest EEPROM data ‐ Screenshot of software availability
NHTSA 原廠通報資料 ↗僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。