查看

MERCEDES-BENZ

LI27.19-P-080869

2026-08-29 · NHTSA 11037210

車型關聯可作查閱線索;引擎、生產範圍與軟體條件請核對原廠資料。

原廠摘要

以下為英文原文

Complaint Temporary no start condition with check engine light and multiple warning messages. When performing a quick test, the following fault code is stored in Y3/14 ‐ Transmission control for 8‐speed dual‐clutch transmission (DKG): P24F100 The wake‐up line of the control unit has a short circuit to positive. Cause Possible signal timing between EZS control unit and Transmission Control Unit (DKG) Remedy As of 7/15/2026, new SCN coding is available for the EZS control unit. IPR will advise to open a TIPS case for EZS (N73), this is due to GLA models requiring support for SCN coding procedure. GLB (X247) and CLA (118) No TIPS case necessary. 1. SCN coding of EZS Control Unit 2. Clear all faults and perform extended road test with multiple drive cycles GLA (H247) Special function password required. 1. Verify if special procedure Central Locking ‐ Development Data is present in EZS (figure 1) 2. Submit a TIPS case to the Powertrain Inbox with the following information: ‐ Initial Quick Test w/ freeze frame data ‐ IPR Result ‐ DKG Control Unit Log ‐ EZS Control Unit Log ‐ Initial EEPROM data ‐ EZS special procedure menu If the vehicle has had this LI performed and P24F100 has returned, please submit a TIPS case to the Powertrain Inbox.

NHTSA 原廠通報資料 ↗

僅在原廠、通報編號、發布日期和完整摘要一致時,才合併重複登錄,並保留原始編號。舊資料仍可查閱;確認明確取代關係後才標示後續版本。1994 年以前的車輛關聯與預設結果分開顯示;未註明年式不等於所有年式適用。