عرض

P0E89 · نشرات الشركة المصنعة

إدراج السيارة هو نقطة بداية للبحث. تحقق من المحرك وفترة الإنتاج والبرمجيات في معلومات الشركة المصنعة.

P0E89 ← ماذا يعني هذا الرمز؟

6 النتائج

LI47.70-P-079912 ↗

MERCEDES-BENZ · 2026-09-29

Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High‐voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU ‐ N127 (Powertrain control unit) • P154900 ‐ There is a warning due to overcurrent in the charging system of the high‐voltage electric circuit. • P154A00 ‐ There is a warning due to a detected crash event at standstill. • P154B00 ‐ There is a warning due to a stuck contactor. DCB223 ‐ N116/5 (Direct current charge connection unit) • P0E8929 ‐ The input current of the on‐board DC charging connection unit is too high. There is an invalid signal. • P2BC500 ‐ The contact ''Positive terminal'' of the contactor in the on‐board DC current charge‐connection…

LI47.70-N-079913 ↗

MERCEDES-BENZ · 2025-11-12

Vehicle not starting after DC charging Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit) • P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit. • P154A00 - There is a warning due to a detected crash event at standstill. • P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit) • P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal. • P2BC500 - The contact ''Positive terminal'' of the contactor in the…

LI47.70-P-079912 ↗

MERCEDES-BENZ · 2025-11-11

Complaint Vehicle will not start after DC charging Warning in the instrument cluster related to High-voltage on board electrical system The following fault codes related to stuck contactor can be found in the High Voltage Control units : PTCU - N127 (Powertrain control unit) • P154900 - There is a warning due to overcurrent in the charging system of the high-voltage electric circuit. • P154A00 - There is a warning due to a detected crash event at standstill. • P154B00 - There is a warning due to a stuck contactor. DCB223 - N116/5 (Direct current charge connection unit) • P0E8929 - The input current of the on-board DC charging connection unit is too high. There is an invalid signal. • P2BC500 - The contact ''Positive terminal'' of the contactor in the on-board DC current charge-connection…

CB25-G-003 ↗

ISUZU · 2025-10-10

CUSTOMER SATISFACTION: IN SOME 2025-2026MY ISUZU NRR-EV VEHICLES, CUSTOMERS MAY EXPERIENCE HIGH VOLTAGE BATTERY CHARGING ISSUES WHERE CHARGING MAY BE UNEXPECTEDLY INTERRUPTED. VEHICLES EXHIBITING THESE CHARGING ISSUES MAY SET DTCS P0E89 OBC INPUT CURRENT TOO HIGH AND/OR P0D22 QUICK CHARGE FAILURE IN THE VEHICLE CONTROL UNIT AND CAUSE THE EV SYSTEM MALFUNCTION AMBER WARNING LIGHT TO ILLUMINATE ON THE INSTRUMENT PANEL. THIS CONDITION MAY BE RESOLVED BY REPROGRAMMING THE VCU WITH A REVISED CALIBRATION.

TSB006722 ↗

TOYOTA · 2023-02-24

TSB: Some 2021 ? 2023 model year RAV4 Prime XSE grade vehicles equipped with a 6.6 kW electric vehicle charger sub-assembly may exhibit a MIL ON condition with one or more of the following Diagnostic Trouble Codes (DTCs): ?P0D2A19 ? Hybrid/EV Battery Charger Input Current Sensor Circuit Current Above Threshold ?P1C1B00 ? PFC Boosting Circuit Malfunction ?P0E8919 ? Charger ?B? Input Current Too High Circuit Current Above Threshold ?P1BD300 ? Charger ?B? PFC Boosting Circuit Malfunction The vehicle may also exhibit an inoperative onboard plug-in charger. Follow the Repair Procedure in this bulletin to address this condition.

T-SB-0067-22 ↗

TOYOTA · 2022-08-15

TSB: Some 2021 ? 2022 model year RAV4 Prime XSE grade vehicles equipped with a 6.6 kW electric vehicle charger sub-assembly may exhibit a MIL ON condition with one or more of the following Diagnostic Trouble Codes (DTCs): ?P0D2A19 ? Hybrid/EV Battery Charger Input Current Sensor Circuit Current Above Threshold ?P1C1B00 ? (PFC Boosting Circuit Malfunction) ?P0E8919 ? (Charger ?B? Input Current Too High Circuit Current Above Threshold) ?P1BD300 ? (Charger ?B? PFC Boosting Circuit Malfunction) The vehicle may also exhibit an inoperative onboard plug-in charger. Follow the Repair Procedure in this bulletin to address this condition.